A running cost estimate is four numbers multiplied and divided: annual heat for space heating, annual heat for hot water, a seasonal efficiency, and a price per kWh. Each carries its own uncertainty, and the efficiency carries the most. The honest output is a range with the assumptions written beside it.
Start from heat demand, not the old bill in pounds
Space heating demand comes from the heat loss calculation and the degree days for the location, or from metered fuel use where the customer has a year of bills. Where you have both and they disagree, look at the gap before you pick one. The bill-based method is set out for homeowners in heat loss surveys and choosing the right size, so a customer may arrive having done it. HeatLens works out the room-by-room heat loss with the assumptions visible.
Record which source you used. If it was fuel use, record the boiler efficiency you assumed to turn kWh of gas into kWh of heat.
An MCS installer also owes the customer the standard estimate in MCS 031 a) before the contract. That one starts from the EPC's space heating and hot water demand, divides space heating by an SPF read from the standard's emitter table and hot water by a fixed 1.9 (2.2 for ground source), adds any immersion use for pasteurising the cylinder, and shows electricity use 10% either side. It gives kWh, not pounds; the form tells the customer they can convert it to approximate running costs. Under the MCS:2025 version, your own estimate can sit alongside it if you explain the method, give it no more prominence, and add a caution where it is much better. SCOP, SPF and performance estimates sets out the steps.
Treat hot water as its own line
Hot water runs at a lower efficiency than space heating, so folding it into one blended figure flatters the estimate. We cut HeatpumpMonitor's rolling 365-day statistics on 15 November 2026 for the 307 air source systems that report hot water separately. The median share of heat going to hot water was 14.9%, and the median share of electricity was 19.4%. Median hot water COP was 3.06 against 4.16 for space heating. These are our calculations from open data on a self-selected group of well-run systems, so use the pattern, not the absolute values.
Choose the efficiency and say which boundary
Running cost follows the electricity the customer pays for, so use an H4 figure. In the Electrification of Heat trial, the median SPF H4 for 428 air source heat pumps was 2.78, with the middle half between 2.55 and 3.05. Measured SPF H2 was below the design SCOP in 91.9% of homes.
That doesn't mean every estimate should be 2.78. It means an estimate well above the trial's upper quartile needs a reason you can point to, such as a low design flow temperature, and that the customer should see a low case as well as a central one. SCOP, SPF and performance estimates has the flow temperature evidence.
Price cap rates for 1 October to 31 December 2026
Ofgem's capped rates for 1 October to 31 December 2026, as a Great Britain average for direct debit customers:
| Unit rate | Standing charge | |
|---|---|---|
| Electricity | 26.32 p/kWh | 54.83 p/day |
| Gas | 7.97 p/kWh | 29.68 p/day |
The gas figures include 5% VAT. The electricity figures carry no VAT in this period, so they are not like-for-like with earlier quarters. Rates vary by region and payment method, so use the customer's region for a real quote. Ofgem's announcement for October to December 2026 says the next cap, for January to March 2027, is due on 25 November 2026.
Time-of-use tariffs change the unit rate, not the method
These are the structures suppliers showed on their own pages on 15 November 2026.
- Cosy Octopus has three cheaper windows every day (04:00 to 07:00, 13:00 to 16:00 and 22:00 to 00:00) priced 51% below the day rate, and a peak from 16:00 to 19:00 priced 50% above it. In the London region in November 2026, Octopus's public API showed 14.12 p/kWh in the cheap windows, 28.80 p/kWh by day, 43.19 p/kWh at peak and a 42.29 p/day standing charge.
- EDF Heat Pump Tracker takes 10 p/kWh off EDF's standard regional rate from 04:00 to 07:00 and 13:00 to 16:00. EDF publishes regional ranges of 25.36 to 27.86 p/kWh by day and 15.36 to 17.86 p/kWh in the windows.
- British Gas Heat Power gives 50% off the unit rate from 00:00 to 07:00 and 13:00 to 16:00, applied as a weekly bill credit. The page shows no p/kWh without a quote.
To use one in an estimate you need the share of the heat pump's electricity that falls in each band, and that depends on controls and on how the home holds heat. Without metered data for the home, that share is an assumption. State it. We have a separate post on heat pump tariffs over a measured year, and smart tariffs and flexible heating has the trial evidence.
Standing charges belong in the comparison
The electricity standing charge is paid either way, so it drops out of a comparison with gas. The gas standing charge only drops out if the gas supply goes. At 29.68 p/day for 365 days, that is £108.33 a year at the October to December 2026 price cap.
Don't present that saving as permanent. On 28 October 2026 the government announced it will end gas standing charges, asking Ofgem to remove them in 2027 or as soon as possible after, with the fixed costs moved into the gas unit rate. The new unit rate has not been published. Removing the gas supply covers this for the homeowner.
Show a range, with the working
Here is the arithmetic for a home needing 10,000 kWh of heat a year, at the capped electricity rate, across the trial's quartiles. It is an illustration of the method, not a typical home.
| Case | SPF H4 | Electricity used | Cost at 26.32 p/kWh |
|---|---|---|---|
| Low | 2.55 | 3,922 kWh | £1,032 |
| Central | 2.78 | 3,597 kWh | £947 |
| High | 3.05 | 3,279 kWh | £863 |
The same heat from gas at 7.97 p/kWh comes to £938 with an 85% efficient boiler and £886 at 90%, before the gas standing charge. The low and high cases are £169 apart, and they sit either side of both gas figures. That is why the efficiency assumption has to be visible.
On the quote, list the heat demand and its source, the hot water allowance, the SPF and its boundary, the tariff with its date and region, and the boiler efficiency used for the comparison. Call it an estimate. The customer's first year of bills is the check, and the estimate should be written so that check is possible.