Most heat pumps run best on weather compensation, left to heat steadily, with at most a small drop in temperature overnight. The CIBSE and HPA UK Domestic Heat Pump Design and Installation Guide (2026) recommends exactly that: a "constant" heating strategy with an optional setback of no more than 3°C (note 620), and weather compensation built into the heat pump (note 623).
The reason is the temperature of the water going to the radiators. The lower it is, the more heat the heat pump gets from each unit of electricity. In the government-funded Electrification of Heat trial, over 30-minute periods, the median was 3.50 units of heat per unit of electricity when sending out water at 35°C, and 2.38 at 55°C (section 3.6). Most of the settings below are about keeping that water as cool as your comfort allows.
Weather compensation sets the water temperature
Weather compensation means the heat pump decides the water temperature from the temperature outside. On the coldest days it sends the design flow temperature; on milder days it sends cooler water (CIBSE note 623). The setting that links the two is usually called the heating curve.
A curve might send 45°C at minus 3°C outside, falling to 30°C at 15°C outside. Your installer should have set it from the design. The aim is the lowest curve that keeps the house comfortable. When Nesta and Bristol City Council reported on 92 audits of heat pumps in social housing (published 5 October 2026), every one had at least one fault, disabled weather compensation among them, and lowering the flow temperature and switching weather compensation on were among the typical fixes. The typical fixes cost about £200 a home, mostly labour.
Tuning the curve yourself
Most controllers let you move the curve up or down, or change its two ends. A simple routine:
- Open the TRVs fully in the main living areas, and set any room thermostat a little above the temperature you want, so neither fights the curve while you tune it.
- If the house is too warm on mild days, lower the mild-weather end of the curve by 1 or 2°C. If it is too cold in cold weather, raise the cold-weather end.
- Change one thing at a time and wait a day or two. A house responds slowly.
- Keep a note of the outdoor temperature, the indoor temperature and what you changed.
If your manual calls the setting something else, such as "slope", "gradient" or "parallel shift", the principle is the same. If you can't find it, ask the installer to show you. The MCS Customer Commitment (Issue 1.1) says an MCS installer will show you how to use the system and agree with you the most effective way to control it for your household (5b, 5c).
Leave it on, with a small setback at most
CIBSE's guide (note 620) says UK homes traditionally heat in morning and evening bursts, which suits boilers but makes a heat pump less efficient. It recommends constant heating, which it explains does not mean the heat pump runs all the time. It means heat is allowed whenever the house asks for it.
If you want it cooler overnight or while you are out, use a setback rather than switching off. The guide recommends a setback no more than 3°C below your comfort temperature (its terminology table puts it at 2 or 3°C), and says a setback stops the house cooling so far that the heat pump has to run hot to recover. In a house with little insulation, it suggests a shorter setback period. Switching the heating off for long spells and running it hard to catch up is one of the common reasons for high bills in troubleshooting high bills or a cold house.
Pre-heating in a cheap tariff window can work alongside this, and running costs and tariffs covers the tariffs. Try any change for a week or two and compare the electricity use.
Thermostats, TRVs and zones
With weather compensation doing most of the work, a room thermostat acts as an upper limit rather than the main control. CIBSE (note 621) suggests one zone for the bedrooms and one for the rest of the house in most homes, with more zones only where rooms are empty for long periods. More zones cost more and can make defrosting harder.
On radiator valves, CIBSE (note 622) recommends TRVs on every radiator except in the room with the main thermostat or sensor. Where the controller and weather compensation already stop rooms overheating, the TRVs can be left fully open. That cuts the resistance the pump has to push against and can lower running costs, while still letting you turn a room down. Closing lots of TRVs and zone valves leaves less water flowing round the system. The heat pump needs that water to melt ice off its outdoor unit, and with too little it tends to stop and start more often.
Stopping and starting
Some stopping and starting in mild weather is normal, because the heat needed can drop below the smallest output the heat pump can run at. Many starts an hour, day after day, suggest something is wrong: a heat pump larger than the house needs, too little water in the system, a curve set too high, or zones and TRVs closing. An installer can read the controller's history and tell you which.
Hot water timing and other settings
CIBSE (note 630) suggests heating the hot water cylinder once a day, in a long block during a setback period, ideally in the middle of the day when the house needs least heat, or otherwise overnight or in a cheap tariff window. Hot water usually takes priority, so the radiators pause while the cylinder heats. MCS's noise guidance suggests running the noisiest operation at the least sensitive times, and gives hot water heating outside sleeping hours as its example (2.3). Hot water and cylinders covers temperatures and the legionella cycle.
Quiet or eco modes lower the fan and compressor speed. The same guidance warns they can reduce heat output, slow hot water recovery and lower efficiency, so use them sparingly.
Smart thermostats and apps that respond to tariff prices are popular. CIBSE (note 611) recommends using the control system supplied or approved by the heat pump manufacturer, because third-party systems can send conflicting commands or cause faults, and says to get the manufacturer's guidance before adding one so the warranty is not affected.
What the handover should leave you with
Under the Customer Commitment, the handover covers a demonstration of the system, how to set it up and use it, and an agreed way to control it (5a to 5c). Ask the installer to write down the curve settings, the hot water schedule and the legionella cycle, and ask for a follow-up visit to fine-tune after the first cold spell. Your first winter with a heat pump describes what to expect while you get used to it.