Home
For homeowners

Air-to-air heat pumps for heating and cooling

How air-to-air heat pumps differ from radiator systems, what MCS requires in every room, the £2,500 grant, hot water, and the planning rules in England.

Last reviewed 16 November 2026 5 min read9 sources

An air-to-air heat pump heats your rooms by blowing warm air from indoor units on the wall, floor or ceiling, instead of heating water for radiators. Most can also cool. It does not heat your hot water, so you need a separate way to do that. Under the MCS design standard, every bedroom and living room gets its own indoor unit.

How it differs from a radiator system

An air-to-water heat pump, the usual kind in the UK, heats water that goes round radiators or underfloor pipes and a hot water cylinder. An air-to-air heat pump is a split system: refrigerant pipes run from the outdoor unit to one or more indoor units, and each indoor unit has a fan that blows air over a heat exchanger. A single split has one indoor unit; a multi split has several on one outdoor unit (MIS 3005-D:2025 definitions).

What follows from that:

  • Rooms warm up quickly, because the unit heats the air directly.
  • There are no radiators or heating pipes to change.
  • Most units can cool in summer.
  • The indoor units are visible, and you will hear the fans and feel the air movement.
  • Hot water needs its own arrangement, covered below.

Because refrigerant is handled on site, the pipework connection is specialist work. GOV.UK's F gas guidance says people who service equipment containing fluorinated refrigerants may need qualifications and company certification to do so. Check what your installer holds before work starts.

Every habitable room gets its own indoor unit

Air-to-air heat pumps came into the MCS design standard in December 2025, in MIS 3005-D:2025 Issue 2.0 and in the original-scheme Issue 3.0. MIS 3005-D:2025 §3.4.3 (Issue 3.0 §5.5.3) sets these rules for an MCS installation:

  • A heat loss calculation for the home, done the same way as for a radiator system (§3.4.3(a)).
  • The outdoor unit, or units, must cover at least 100% of the whole home's heat load at the design outdoor temperature (§3.4.3(d)).
  • The indoor units together must cover at least 100% of the home's heat load (§3.4.3(f)).
  • Each indoor unit must cover at least 100% of the heat load of the room it is in (§3.4.3(g)).
  • Every habitable room must have an indoor unit (§3.4.3(h)).
  • The contract must state what share of the home's hot water, if any, the air-to-air heat pump is designed to provide (§3.4.3(i)).

The standard defines a habitable room as one used for living or sleeping. Bathrooms and toilets, rooms used only for cooking, halls and corridors, and utility, laundry and service rooms are not habitable rooms. For those, and for any room where a unit cannot be fitted, the installer should consider whether it needs heating and, if so, how, for example with a separate heater.

So an MCS design does not rely on warm air drifting from one room to the next to heat the bedrooms and living rooms. If a quote shows one large indoor unit in a hallway heating the whole house, ask how it meets §3.4.3. Because each indoor unit is sized for its own room, the indoor units added together will often be bigger than the outdoor unit, and the standard says that is expected. The installer guide on design temperatures and sizing sets out the full rule.

Hot water needs a separate answer

An air-to-air heat pump heats air, not water. You will still need a way to heat water, such as a cylinder with an immersion heater, a cylinder with its own small heat pump, or an existing system you keep. Hot water, cylinders and legionella covers the options. Ask the installer to show in the contract how hot water will be heated and what share, if any, comes from the heat pump, since MIS 3005-D:2025 §3.4.3(i) requires it to be stated.

How the performance estimate is worked out

An MCS installer gives you a yearly energy estimate before you sign. For air-to-air heat pumps that follows MCS 031 b) Issue 1.0. It covers heating only: the standard says cooling is outside its scope. In its customer information (section 4) it assumes a seasonal performance factor of 3.42, taken from the minimum efficiency that EU Regulation 206/2012 sets for air conditioners, and says this is an assumption that can change with how the system is run. Where the heat pump would also heat water, the estimate uses a factor of 1.9 for that part.

Using the heat pump for cooling in summer adds electricity that is not in the estimate.

The grant and who it suits

In England and Wales, the Boiler Upgrade Scheme gives £2,500 towards an air-to-air heat pump. Ofgem's page for property owners sets these conditions:

  • it is for residential buildings only;
  • the new system must replace an existing fossil fuel or electric heating system, not a low-carbon one;
  • the new heating system as a whole must be able to meet the home's full space heating and hot water needs. Ofgem's page does not say how this applies to an air-to-air heat pump, which does not heat water, so ask your installer how the hot water will be provided;
  • hybrid systems, such as a heat pump alongside a gas boiler, are not eligible;
  • the installer must be MCS certified, and applies for the grant on your behalf.

That makes air-to-air a natural fit for homes heated by storage heaters or electric panel heaters, and for homes where the whole heating system is being replaced. It does not suit a home that wants to keep its gas boiler for heating. The £7,500 grant is for air-to-water and ground source heat pumps. See the Boiler Upgrade Scheme guide.

In Scotland, Home Energy Scotland states that air-to-air heat pumps are not eligible for its grant and loan.

Planning and noise in England

In England, an air source heat pump can be installed as permitted development, without a planning application, if it meets a list of conditions. The Planning Portal says the unit must not be used solely for cooling, so one that heats and cools can qualify. The outdoor unit must not exceed 1.5 cubic metres on a house or 0.6 on a block of flats, and a detached house can have two units under these rights, other homes one. The installation must comply with MCS 020 a), whose noise calculation must come out at or below 37.0 dB(A) at the assessment positions (MCS 020 a) Issue 1.1). Listed buildings and some walls in conservation areas are excluded. Noise, planning and siting covers the detail.

From 24 March 2027, the 2026 edition of Approved Document L for England (paragraph 4.12) says a heat pump that both heats and cools should in most cases be designed to work best at heating.

Air-to-air or air-to-water

Choose air-to-water if you want whole-house heating and hot water from one system through radiators or underfloor heating, and the larger grant. Choose air-to-air if you are replacing electric heaters, if cooling matters to you, or if the home suits a small number of well-placed indoor units, and plan the hot water separately. Ground source, hybrids and other alternatives compares the other options.

Sources

What this guide relies on, and the date we read each one. Rules, prices and standards change, so check the source before you act on a figure.

  1. Ofgem, Boiler Upgrade Scheme, property ownersofgem.gov.uk, read 16 November 2026
  2. Home Energy Scotland, Home Energy Scotland Grant and Loanhomeenergyscotland.org, read 16 November 2026
  3. MCS, MIS 3005-D:2025 Heat Pump Design Standard, Issue 2.0mcscertified.com, read 16 November 2026
  4. MCS, MIS 3005-D Issue 3.0 (alongside MIS 3005-D:2025), The Heat Pump Standard (Design)mcscertified.com, read 16 November 2026
  5. MCS, MCS 031 b) Issue 1.0, Air to Air Heat Pump Pre-sale Information and Performance Calculationmcscertified.com, read 16 November 2026
  6. Planning Portal, Air source heat pumps, planning permissionplanningportal.co.uk, read 16 November 2026
  7. MCS, MCS 020 a) Issue 1.1, Heat pump planning standard for permitted developmentmcscertified.com, read 16 November 2026
  8. HM Government, Approved Document L Volume 1, Dwellings, 2026 editiongov.uk, read 16 November 2026
  9. GOV.UK, Fluorinated gas (F gas), guidance for users, producers and tradersgov.uk, read 16 November 2026

Quick answers on this subject

Still have a question?Ask it and get an answer with sources. No sign-up needed.

From the blog

More on this topic

Guidance only. It is not a substitute for a survey or a professional design for your home.

We'd like to use a Google Ads cookie to measure how people find HeatLens. It's off unless you accept.