Home
For homeowners

Ground source, hybrids and other alternatives to air source

How ground source, hybrid and high-temperature heat pumps, heat batteries and direct electric heating compare with an air-to-water heat pump, on UK trial results and the CIBSE design guides.

Last reviewed 16 November 2026 7 min read13 sources

An air-to-water heat pump, the kind that takes heat from outside air and feeds radiators and a hot water cylinder, is the standard choice, and Nesta's overview of heating technologies (February 2025) says air source suits most UK homes. This guide covers the alternatives, drawing on UK trial results and on the two CIBSE design guides published in 2026.

Air-to-air heat pumps, which blow warm air instead of heating radiators, have their own guide.

The benchmark is an air-to-water heat pump

The best UK measurements come from the Electrification of Heat project, which monitored heat pumps in ordinary homes. Its final performance analysis (December 2024), with monitoring to September 2023, gave 428 air source heat pumps a median seasonal efficiency of 2.78, meaning 2.78 units of heat for each unit of electricity over a year, including back-up heaters and pumps. Efficiency drops in cold weather: over half-hour periods the median fell to 2.37 at -3°C outside and 2.30 at -5°C. (SCOP, SPF and performance estimates explains how these figures are counted.)

Every alternative below is judged against that.

Ground source heat pumps

A ground source heat pump takes heat from pipes buried in trenches or boreholes. Nesta lists ground source, and ground arrays shared between several homes, as alternatives where air source fits less well.

The CIBSE and Heat Pump Association design and installation guide (2026) describes ground source as typically very efficient and consistent, because the ground stays at a fairly steady temperature through the year. It is also more complex and expensive to install than air source. The groundworks need space and cause disruption, environmental permissions may be needed, and the guide sees it as best suited to larger homes, rural sites or big gardens, and higher budgets (Introduction).

Ground source was a small part of the Electrification of Heat trial: the install report puts individual ground source at 1% of installations and shared-loop ground source at 4%. The final analysis covered only 23 ground source homes and advises against using its result as a reference figure. It did find the cold had much less effect on them: at -5°C outside, their median half-hour efficiency was 3.10, against 2.30 for air source. If you are quoted for ground source, ask what seasonal efficiency the design assumes and how it compares with an air source quote for the same house.

The grant is the same as for air source. In England and Wales the Boiler Upgrade Scheme pays the same £7,500 for ground source as for an air-to-water heat pump, and its vouchers are valid for six months instead of three, according to GOV.UK and Ofgem.

Air-to-water or ground source heat pump

£7,500

The same, replacing oil or LPG off the gas gridfrom 21 July 2026 to 31 March 2027

£9,000

Biomass boilerlimited rural cases

£5,000

Air-to-air heat pump

£2,500

Boiler Upgrade Scheme grants in England and Wales. Source: Ofgem and GOV.UK scheme pages, read 15 November 2026.

Boiler Upgrade Scheme grant amounts by technology in England and Wales.

Hybrid systems

A hybrid pairs a heat pump with a gas boiler. Hybrids were 21% of installations in the trial's 2022 report, so there is real data. In the final analysis of 94 hybrids, the heat pump part had a median efficiency of 2.50 (SPF H4), lower than the 2.78 for heat pumps working alone, and it met a median 40% of the home's space heating. The rest came from the boiler. Heat pumps that did a larger share of the work tended to be more efficient. The trial's hybrids were set up to run at lowest cost, and the report notes that other settings might have given different results.

In other words, in that trial a hybrid heat pump did less than half the heating and you keep the gas connection, the boiler servicing and the standing charge. Hybrids are not eligible for the Boiler Upgrade Scheme, and the Home Energy Scotland grant excludes them too. Both schemes require the heat pump to meet the home's full heating demand.

The CIBSE and HPA guide sees a hybrid as a transitional option where a heat pump alone is not possible, for example because the electricity supply is too small or planning limits the size of the outdoor unit. It notes the carbon savings are lower, and says hybrids should not be specified in designs that follow the guide, because of the extra complexity in design and controls (Note 811).

High-temperature heat pumps

A high-temperature heat pump can send hotter water to the radiators, closer to what a boiler does, so fewer radiators need changing. CIBSE's Domestic Heating Design Guide (DHDG, 2026) describes them as producing water at 55 to 80°C, and as intended mainly for replacing a boiler where the radiators were sized for hotter water (Appendix A.6.5). In the trial's final analysis, 183 of the 428 air source heat pumps were high-temperature models, and they performed about as well as the others over a year. The report explains why: most of them seldom ran hot. Of those that went above 65°C at all, 139 of 165 did so for less than 1% of the time, and the report puts much of the result down to weather compensation and the refrigerants used.

That does not mean running hot is free. Across all the heat pumps, the median half-hour efficiency was 3.50 when making water at 35°C, 2.38 at 55°C and 2.02 above 65°C. Radiators and flow temperature explains why. In England, Approved Document L says a wet heating system that is newly installed or fully replaced should be sized to work at a water temperature of 55°C or lower, or the lowest that is feasible where it is not (2021 edition, paragraph 5.10; 4.10 in the 2026 edition). The MCS design standard asks installers to avoid high-temperature heat pumps unless a flow above 55°C is needed, and to offer you a 55°C design alongside any hotter one so you can compare (MIS 3005-D:2025 §3.4.4 and §3.4.5 (Issue 3.0 §5.5.4 and §5.5.5)). A high-temperature heat pump is most useful as headroom for the few rooms where bigger radiators will not fit.

Heat batteries

A heat battery stores heat in a material that melts and solidifies, and takes less room than a hot water cylinder. In the trial, 33 flats were given one because there was no space for a cylinder. The DHDG treats heat batteries and other phase-change stores as outside its scope and recommends manufacturer and expert advice for them (section 4.5). If one is offered as your main heating, charged from cheap-rate electricity, ask for measured annual electricity use from a comparable home.

The government has decided in principle to add a £2,500 Boiler Upgrade Scheme grant for heat batteries once standards and consumer protections are in place, according to the consultation outcome. It was not available on 16 November 2026.

Direct electric and infrared heating

Direct electric heating turns each unit of electricity into one unit of heat. Nesta groups panel heaters, storage heaters and electric boilers here and describes them as "much less efficient" than heat pumps: cheap to install, costly to run and harder on the electricity grid.

The running cost follows from prices. Under Ofgem's price cap for October to December 2026, electricity averages 26.32 p/kWh and gas 7.97 p/kWh on standard tariffs. 26.32 divided by 7.97 gives 3.30, so a unit of electricity costs about 3.3 times a unit of gas. A heat pump at the trial's median of 2.78 roughly cancels that out. A direct electric heater does not, so the same heat costs around three times as much as from gas, unless most of it is bought at off-peak rates. Running costs and tariffs has more.

Infrared panels warm people and surfaces instead of the air. The DHDG lists them with the other fixed electric heaters, as electric radiant heaters, and notes that because the air is not heated directly, less heat is lost when an outside door is opened (Appendix A.6.6). An infrared panel is still a resistance heater, turning each unit of electricity into one unit of heat, so the running cost comparison above applies to it too. If you are quoted a saving, ask for the measured annual electricity use of a comparable home, and who measured it.

The DHDG also makes a fair point in the other direction: for a home with very low heat loss, a full system of pipes and radiators may be unnecessary or unaffordable, and fixed electric heaters can be the sensible choice (Appendix A.6.6).

How to choose between them

If an air-to-water heat pump fits your home, the trial evidence gives no reason to prefer a hybrid, and ground source is worth pricing mainly where there is land and budget for the groundworks. If it doesn't fit, the reason usually decides the alternative: no outdoor space points to a shared ground array or air-to-air, no cylinder space to a heat battery for hot water. Flats and small homes works through those cases, and is a heat pump right for my home? covers the wider decision.

Sources

What this guide relies on, and the date we read each one. Rules, prices and standards change, so check the source before you act on a figure.

  1. Nesta, Domestic heating technology optionsnesta.org.uk, read 15 November 2026
  2. Energy Systems Catapult, Electrification of Heat, insights from heat pump performance data (December 2024)esc-production-2021.s3.eu-west-2.amazonaws.com, read 16 November 2026
  3. Energy Systems Catapult, Electrification of Heat Home Surveys and Install Reportes.catapult.org.uk, read 15 November 2026
  4. GOV.UK, Apply for the Boiler Upgrade Scheme - what you can getgov.uk, read 15 November 2026
  5. Ofgem, Boiler Upgrade Scheme - property ownersofgem.gov.uk, read 15 November 2026
  6. GOV.UK, Boiler Upgrade Scheme and certification requirements for clean heat schemes - consultation outcomegov.uk, read 15 November 2026
  7. Home Energy Scotland, Grant and Loanhomeenergyscotland.org, read 15 November 2026
  8. HM Government, Approved Document L Volume 1 Dwellings (2021 edition incorporating 2023 amendments)assets.publishing.service.gov.uk, read 16 November 2026
  9. HM Government, Approved Document L Volume 1 Dwellings (2026 edition)gov.uk, read 16 November 2026
  10. MCS, MIS 3005-D:2025 Issue 2.0, heat pump design standardmcscertified.com, read 16 November 2026
  11. Ofgem, Changes to the energy price cap between 1 October and 31 December 2026ofgem.gov.uk, read 15 November 2026
  12. CIBSE and HPA, Domestic Heat Pump Design and Installation Guide (2026)cibse.org, read 16 November 2026
  13. CIBSE, Domestic Heating Design Guide (2026)cibse.org, read 16 November 2026
Still have a question?Ask it and get an answer with sources. No sign-up needed.

From the blog

More on this topic

Guidance only. It is not a substitute for a survey or a professional design for your home.

We'd like to use a Google Ads cookie to measure how people find HeatLens. It's off unless you accept.